low voltage pool light wiring junction box mike holt However, your comment that you normally run the cord directly to the xformer or switch is an issue. While the code does not explicitly require a pool light junction box, as a practical matter it does as it is the only way to comply . $28.00
0 · underwater pool junction box
1 · swimming pool junction boxes
2 · swimming pool junction box requirements
3 · pool light junction box requirements
4 · pool light junction box
5 · pool light box
What's a good way to mount a wallpack on corrugated metal siding? I've tried every method, and the only thing that's even halfway satisfactory are old-fashioned toggle bolts right .
underwater pool junction box
where can i get sheet metal
swimming pool junction boxes
Is it acceptable to use a standard pvc box to terminate low voltage pool lights in as opposed to a specific pool box with strain relief clamps for the cords? I'm at a job where the .The #8 just bonds to the inside of a niche or forming shell and is run back to the . However, your comment that you normally run the cord directly to the xformer or switch is an issue. While the code does not explicitly require a pool light junction box, as a practical matter it does as it is the only way to comply .
The #8 just bonds to the inside of a niche or forming shell and is run back to the junction box for the lights. Normally that is for line voltage (120V) lights. If a metal raceway is .The junction box (deck box) that connects directly to an underwater permanently installed pool luminaire forming shell must be [680.24(A)(1)]: Listed, labeled, and identified as a swimming pool junction box. From the links that Splatz posted it clearly states that the box has to be 4" above the pool deck "AND" 8" above the water line. This box can be .
• Verify that all lighting is located at least 10 feet from pool water unless listed for low- the voltage contact limit and supplied by a transformer listed for swimming pools. • Ensure that all . It sounds like you used the same junction box for both the 120V primary and low voltage light connections. I’m not sure if that’s permissible or not, but I wouldn’t do it that way. .
where is a junction box located
Low voltage lights are 12 volts or more, while as little as 6 volts can immobilize children. Mike Holt also has a 7-hour series of videos on testing a pool’s electrical safety, . We just had the pool resurfaced and I decided to run conduit around the exterior of the deck and penetrate it close to where the original wiring still is. So now I've got the conduit run and the old junction box is about 2' . You have to have a listed pool light junction box somewhere between the light and the transformer-the conduit from the light can not extend directly to the transformer. Keep in . the low voltage contact limit or less, the junction box location shall be permitted to comply with (A)(2)(c). (a) Vertical Spacing. The junction box shall be located not less than 100 mm (4 in.), measured from the inside of the bottom of the box, above the ground level, or pool deck, or not less than 200 mm (8 in.) above the maximum pool water .
I ran from the breaker to the switch then to the transformer to the pool light junction box. I terminated the grounding conductor at all of those points. At the transformer I tapped off the 14 volts with two #12. . but I wouldn’t do it that way. Keep the low voltage wiring separated from 120V. J. Jimmy7 Senior Member. Location Boston, MA .Junction box height was not mentioned in this article. A common problem is that they are located to low to the overflow of the pool and subject to water entering the connection area for the pool light. The incorporated plugs and washes in . Basically if you run PVC conduit to a wet niche light (not low voltage or LED) you have to run an extra wire that is a jumper to the EGC. It is sort of a redundant ground. It has to be an insulated #8 and it goes from the inside of the niche back to the junction box for the lights and lands on the EGC bar.
This transformer is specifically listed for this use and is an isolated winding type transformer with an ungrounded secondary similar to the low-voltage landscape lighting transformer, as required by 411.5(B). The low-voltage pool lighting transformer has one additional feature in its design.
Hayward Color Logic Led lights have a #8 bond wire that runs back to the pool light junction box but no gfi protection on the circuit. Savi Melody Led pool lights made by Nexxus lighting, fit into IIRC an 1 1/2" pvc pipe for the light shell and do not require the #8 bond wire.
(A) Junction Boxes. A junction box connected to a conduit that extends directly to a forming shell or mounting bracket of a no-niche luminaire shall meet the requirements of this section. (1) Construction. The junction box shall be listed, labeled, and identified as a swimming pool junction box and shall comply with the following conditions:
Yes, this is a big mess. You definitely have a listing issue with the pool light itself that must be corrected or dealt with. And refer them to 680.24(B) in regard to the pool light junction box/transformer issue. Unless the transformer enclosure meets the provisions of this section, a junction box as described in 680.24(A) must be used.
If the brass conduit is visible at the deck/junction box, I would attach a bond wire to that and also to the grid if it's available. I've been servicing pools since the early 80's. Of course at that time pools lots of pools were built in the 60's and 70's. A few from the 50's. Some of them used 1/2" steel conduit on the pool lights. Hi All, I am working on a new pool that has a total of (12)120v LED light fixtures with a total 7.2amps. Six lights on one side, six on the other. Being supplied from at 20a Siemens GFI bolt-on breaker. Breaker supplies a switch and from the switch it . I stuck a flash light and a mirror in the hole and located a blue junction box with 3 - cables going to it. The box was not even pointing down towards the sheetrock, so I had to cut the mounting nails and rotate it 90 degrees. 680.32 (F) (1) Wiring Methods. Branch-circuit wiring on the supply side of enclosures and junction boxes connected to conduits run to wet-niche and no-niche luminaires (fixtures), and the field wiring compartments of dry-niche luminaires (fixtures), shall be installed using rigid metal conduit, intermediate metal conduit, liquidtight flexible nonmetallic conduit, or .
Low Volt LED pool light junction box question??? Thread starter billymons; Start date Apr 21, 2016; Status Not open for further replies. B. billymons Member. Location Kutztown, Pa. Apr 21, 2016 #1 I'm doing the electric on my in ground pool and have done a lot of research on the codes but I have a question about the low voltage LED lights. It .
While some may think that only Chapters 7 and 8 relate to these systems, the reality is that they are typically installed in a Chapter 3 wiring method, cabinet, or box so almost every chapter in the NEC applies. This textbook narrows down which rules relate to low voltage installations, and helps you understand how and when they should be applied. This time the other end of the same wire was melted too. The problem is in the 12 volt wires of the circuit. There is no sign of water in the junction boxes. The system is this: . I’m having a problem with the low voltage wires for a swimming pool light melting. Am I correct that the pool listed transformers are built in such a way that it is impossible for the high voltage to get into the low voltage wiring? J. JFletcher Senior Member. Location Williamsburg, VA. Jul 19, 2017 #2 You do not need GFCI protection on pool lights operating at 15V or less. That said, you probably need GFCI protection for the .
My understanding is that a PVC conduit must go from the light housing to the fixture and the low voltage wire from the light will be ran in there. My questions are: . The stopper comes with the pool light junction box. The connection needs to be covered as you mention; it is the most vulnerable part. . The wire connected to the outside is . I'm doing the underground on a McMansion here and part of the scope is the pool equipment. There are 30 LED lights in the pool. Can I bring these into a 3R gutter the feed the gutter with a couple trannys that comply with 680.23(A)(2)? The fixtures will be installed in a 2" PVC sched 40 below.
• Check to be sure that the voltage to the pool light(s) doesn’t exceed 15V and is supplied by a listed transformer for swimming pools. Step 6. Inspect Pool Wiring.Download one of the documents below . containing the . NEC. requirements for swimming pools .
680.24 Junction Boxes and Electrical Enclosures for Transformers or Ground-Fault Circuit Interrupters. (A) Junction Boxes. . That would be rare today as almost all pool lights are low voltage today even though the code still recognizes 120 volt lights. . I have never seen a pool light box like that one shown. The ones we see are brass .
LED Highbay has 2 cords coming out of the housing with a hook mount. One 3c 14ga cord is for the 120v Power, One 2c 16ga cord is for the 0-10v dimming. All will be in a warehouse, all surface mount exposed conduit installation. The plan is to hang the fixtures on an eyebolt and piping to each.
It is a low voltage, 'dry niche' type and the bulb is changed via a flush mounted deck box on the pool deck. We have a world wide patent on this product and are trying to bring it into the US, but are struggling to comprehend the US coding requirements as they differ significantly from Europe. Re: Please help me understand pool bonding The #8 solid copper wire also has to run from the equipotential grid of the pool walls to the frame of the pool pump. This is a completely different equipment ground from the one for the pool light. 120 volt underwater lights are . If the lights are plastic and also low voltage you don't have to bond them but make sure of that before filling the pool. Some niches are plastic but the ring holding in the light is metal, so that needs bonding. These are usually 120V lights. Most pool lights these days are low voltage LED and require no bonding.
Wiring huge house and starting all the low voltage lines from 120v. transformers to undercabinet lighting, cove lighting, etc. and started to wonder today what others are using for the 12 - 24 volt low voltage wire in lighting installs. Typically I have always used a #12 zip style cord. But that’s a far cry from loose, unsecured wiring in a pull box compared to secured and landed on terminals. And NEC is pretty clear that outside of equipment general wiring and low power are separate just as you don’t run low voltage and medium voltage wiring together. So it seems like the issue here is you need more, smaller pull boxes. Common misconception about Article 725 is that it allows CL2 or similar "thermostat wire" or "bell wire" to be used on "low voltage" circuits. The common bell cable that is used in residential settings and installed for door bells, is not listed per Article 725 as being classified for class 1, 2, or 3. circuits.